Measurements for different applications can be added to the module. It is also possible to mix measurements by adding different types of modules.
Input module can be expanded to accommodate a wide variety of measurement.
Each of the 10 units can include a different input/output module (*1)
Up to 10 input/output modules of the same kind can be attached to one main unit(*1)
Maintains the maximum sampling speed even when the number of input modules for voltage or voltage/temperature are increased.
* In the high-speed voltage module and Logic/Pulse module, the maximum sampling speed varies by selected data storage device.Up to 10 units of the GL7000 can be connected to 1PC through LAN or USB and controlled using the software.
The start/stop, trigger and sampling can be synchronized in the GL7000 when they are connected by a sync. cable. The master and slave units are automatically identified.
*The sync. cable is optional (B-559).
Measurement settings and signal measurement can both be done without a PC by attaching the display module. The display module can be moved to different locations for remote operation by connecting it to the main module with a LAN cable*, it also can be embedded into the system. The module can stile be operated by the PC even when the display module is connected.
* Up to 10m using CAT5 LAN cable (straight connection)
Utilizes a bright clear TFT color LCD monitor.
Makes it easy to read data in waveform or digital form and to check measurement parameter settings.
Y-T display
Digital display
XY display
FFT display
Function Menu
Easy access to each functions from listed icons.*
* It s required firmware version 2.00 or later.
Touch the icon, move to the
next setting menu screen.
The display waveform is able to
expand or shrink.
Built-in RAM | RAM is built into each modules to allow saving of up to 2 million samples for each channel. Increasing the number of channels does not decrease the data capture duration. |
Built-in Flash memory (*1) | 4GB of Flash memory is built into the main module. Captured data can be saved directly to the flash memory when sampling speed is less than 1kS/s (1ms). Non-volatile memory (saved data is retained even if the power is turned off). |
SD memory card (*2) | SD card slot (supports SDHC, up to 32GB) is standard on the main module. Captured data can be saved directly on the SD card when sampling speed is slower than 1kS/s (1ms). Supports hot-swap where SD memory card can be replaced during recording without any data loss. (*3) |
SSD module (128GB) (*1)(*2) | Allows multiple recording of large amount of data to be saved when optional SSD module is used. It has a high vibration resistance and the captured data can be saved directly to the SSD when sampling is not faster than 1MS/s (1μs). (*4) |
Maximum sampling speed and the data capturing time
Input Module |
Storage Device | Number of units, Max. sampling speed (interval) | ||
Attached to 1 or 2 modules |
Attached to 3 or 4 modules |
Attached to 5 to 10 modules |
||
![]() Hi-speed Voltage module GL7-HSV |
Built-in RAM (2 M samples) | 1MS/s (1μs) | ||
Built-in Flash memory (4GB) | 1kS/s (1ms) | |||
SD memory card (32GB) (*4) | ||||
SSD (128GB) (*4) | 1MS/s (1μs) | 500KS/s (2μs) | 200KS/s (5μs) | |
![]() High Voltage module GL7-HV |
Built-in RAM (2 M samples) | 1MS/s (1μs) | ||
Built-in Flash memory (4GB) | 1kS/s (1ms) | |||
SD memory card (32GB) (*4) | ||||
SSD (128GB) (*4) | 1MS/s (1μs) | 500KS/s (2μs) | 200KS/s (5μs) | |
![]() DC Strain module GL7-DCB (*5) & ![]() Charge module GL7-CHA |
Built-in RAM (2 M samples) | 100kS/s (10μs) | ||
Built-in Flash memory (4GB) | 1kS/s (1ms) | |||
SD memory card (32GB) (*4) | ||||
SSD (128GB) (*4) | 100kS/s (10μs) | |||
![]() Voltage module GL7-V |
Built-in RAM (2 M samples) | 1kS/s (1ms) | ||
Built-in Flash memory (4GB) | ||||
SD memory card (32GB) (*4) | ||||
SSD (128GB) (*4) | ||||
![]() Voltage / Temp. module GL7-M |
Built-in RAM (2 M samples) | 100S/s (10ms) | ||
Built-in Flash memory (4GB) | ||||
SD memory card (32GB) (*4) | ||||
SSD (128GB) (*4) |
Input Module |
Storage Device | Capturing time (Attached 1 module *Attached 10 modules) | ||||
1MS/s (1μs) |
100KS/s (10μs) |
1KS/s (1ms) |
100S/s (10ms) |
1S/s (1s) |
||
![]() Hi-speed Voltage module GL7-HSV |
Built-in RAM (2 M samples) | 2sec. (2sec.) |
20sec. (20sec.) |
App. 33min. (App. 33min.) |
App. 5hrs. (App. 5hrs.) |
App. 23days (App. 23days) |
Built-in Flash memory (4GB) | N/A | N/A | App. 72hrs. (App. 10hrs.) |
App. 32days (App. 4days) |
App. 3269days (App. 440days) |
|
SD memory card (32GB) (*4) | App. 83hrs. (App. 11hrs.) |
App. 34days (App. 4days) |
App. 3495days (App. 470days) |
|||
SSD (128GB) (*4) | App. 4min. (N/A) |
App. 44min. (App. 6min.) |
||||
![]() High Voltage module GL7-HV |
Built-in RAM (2 M samples) | 2sec. (2sec.) |
20sec. (20sec.) |
App. 33min. (App. 33min.) |
App. 5hrs. (App. 5hrs.) |
App. 23days (App. 23days) |
Built-in Flash memory (4GB) | N/A | N/A | App. 109hrs. (App. 17hrs.) |
App. 45days (App. 7days) |
App. 4577days (App. 715days) |
|
SD memory card (32GB) (*4) | App. 117hrs. (App. 18hrs.) |
App. 48days (App. 7days) |
App. 4893days (App. 764days) |
|||
SSD (128GB) (*4) | App. 4min. (N/A) |
App. 44min. (App. 11min.) |
||||
![]() DC Strain module GL7-DCB (*5) & ![]() Charge module GL7-CHA |
Built-in RAM (2 M samples) | N/A | 20sec. (20sec.) |
App. 33min. (App. 33min.) |
App. 5hrs. (App. 5hrs.) |
App. 23days (App. 23days) |
Built-in Flash memory (4GB) | N/A | App. 72min. (App. 13min.) (Using 10 units of GL7-CHA modules: 10 hours) |
App. 32days (App. 5days) (Using 10 units of GL7-CHA modules: 4 days) |
App. 3269days (App. 544days) (Using 10 units of GL7-CHA modules: 440 days) |
||
SD memory card (32GB) (*4) | App. 83min. (App. 13min.) (Using 10 units of GL7-CHA modules: 11 hours) |
App. 34days (App. 5days) (Using 10 units of GL7-CHA modules: 4 days) |
App. 3495days (App. 582days) (Using 10 units of GL7-CHA modules: 470 days) |
|||
SSD (128GB) (*4) | App. 44min. (App. 6min.) |
|||||
![]() Voltage module GL7-V |
Built-in RAM (2 M samples) | N/A | N/A | App. 33min. (App. 33min.) |
App. 5hrs. (App. 5hrs.) |
App. 23days (App. 23days) |
Built-in Flash memory (4GB) | App. 42hrs. (App. 4hrs.) |
App. 17days (App. 2days) |
App. 1760days (App. 204days) |
|||
SD memory card (32GB) (*4) | App. 45hrs. (App. 5hrs.) |
App. 18days (App. 2days) |
App. 1882days (App. 218days) |
|||
SSD (128GB) (*4) | ||||||
![]() Voltage / Temp. module GL7-M |
Built-in RAM (2 M samples) | N/A | N/A | N/A | App. 5hrs. (App. 5hrs.) |
App. 23days (App. 23days) |
Built-in Flash memory (4GB) | App. 17days (App. 2days) |
App. 1760days (App. 204days) |
||||
SD memory card (32GB) (*4) | App. 18days (App. 2days) |
App. 1882days (App. 218days) |
||||
SSD (128GB) (*4) |
Dual-Sampling Feature *
Dual sampling speed can now be configured at the same time. While recording long intervals on the slow sampling speed, trigger set can start recording dynamic transient signals at a fast sampling speed.
* It is required firmware version 2.0 or later.
Enhanced relay recording function *
Up to 4GB data files can be recorded on a relay mode where no data loss occurs in between the files. This offers long term recording of dynamic data recording. Relay mode captures all data in between the data files eliminating data loss.
* The file for recording data is limited up to 4GB on firmware version 2.0 or later, 2GB on firmware version 1.6 or before.
Ring mode
Saves most recent data of specified number after recording stops.
Number of capturing data 1000 to 10000000 data
* When using built-in RAM, 10 to 4000000 data
Back up recording data
The data file can be created periodically for purpose of backing up data while recording it, and the file is automatically transferred to another storage device on the unit or FTP server on the network.
Backup interval: 1, 2, 6, 12, 24 hour(s)
Backup file destination: SD memory card, SSD module (optional), FTP server
Data file format: GBD (binary) or CSV (text)
* The CSV format is available with firmware version 2.10 or rater.
• Available sampling speed is the 10 ms or slower when using the CSV format.
• When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
• The storage device specified as the recording destination of the measurement data can not be set as the transfer destination of the backup file.
• When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.
Other functions *
Function | Description |
Set time interval in between trigger repeat | Trigger repeat can not be activated based on START trigger and STOP trigger with set time interval. |
Start/Stop Message On/Off Feature | Start/stop message will not have a on/off confirmation message. |
SD memory card exchange | The SD card can be replaced during recording when the sampling interval is 100ms or slower. |
Data search | Specific value (measured value, alarm point) of a particular channel in the recorded data can be searched and found automatically. |
Movement by cursor | The cursor can be moved automatically to a specified time in the recorded data. |
Statistical calculation with cursor | The statistical calculation (average, max, min, P-P, effective value) can be determined in between the recorded data specified by the cursor. |
Supports Ethernet and USB2.0
Ethernet (10BASE-T, 100BASE-TX) and USB2.0 (hi-speed) interface are standard.
Each interface port is located in the front of the unit for easy cable connection.
It supports the following functions.
WEB server, FTP server function | It can be controlled by using a WEB browser, and signal can also be monitored. It supports accessing the captured data in memory device. |
FTP client function | Captured data is periodically transferred to the FTP server for backup. |
DHCP client function | The IP address of the GL7000 is automatically obtained from the DHCP server. |
NTP client function | The clock on the GL7000 is periodically synchronized with the NTP server. |
USB drive mode | GL7000 can emulate an external USB device for quick data file transfer when is is started in the USB drive mode. The file in the memory device can be transferred to the PC by drag & drop feature. |
Software Development Kit (SDK) is available for real time data transfer and beyond for custom application developed for your need.
* Module type library for LabVIEW will be available in December.
Tool to make the GL7000 portable. (It support unit with up to three modules installed.)
Trunk case for carrying or storing GL7000. It support unit with up to three modules. (It is not for shipping, it can not bear heavy impacts such as falling.)
Input connector for GL7-DCB module, it enables to connect wires from the sensor with screws. It can be used without the upper cover of connector.
(Bracket (B-560AP) for holding input terminal board is included.)
Cable connecting the input connector (B-560A) to the GL7-DCB modul.